Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9752374
| No.9752374
- Product Categories
- Friendly Links
| Information Name: | Zhucheng transfer Weichai 50 kilowatts used diesel generator sets, 2015 market |
| Published: | 2015-06-25 |
| Validity: | 120 |
| Specifications: | 50 kilowatts |
| Quantity: | 5.00 |
| Price Description: | |
| Detailed Product Description: | Weichai 50 kilowatts used diesel generator sets, 2011 production, the wood 150 kilowatts, 2013 INDUSTRY Shangchai 120 kilowatts, 2012 production, Yuchai 250 kilowatts, 2012 loom normal power generation capacity, rapid start, preferential transfer. Used diesel generators operating skills: 8 Use tips generators after the start, many of my friends think that diesel generators do not how to take care after normal start, but in fact this is wrong, because the diesel generator set is the easiest start after When a fault. So this time it should carry out regular routine checks, so as to ensure generators work properly. Here's a look at starting after 8 Use skills 1, the regulator selection switch to the manual position switch screen; 2, open the fuel switch, while the fuel control lever turn the throttle position is fixed at 700 / minute or so; 3, with high-pressure pump switch handle continuous manual pump oil until the oil resistance pump injector ringing say a word so far; 4, the pump switch handle on the working position, the valve to the decompression position; 5 with hand lever or press the electric start button to start the diesel engine when the diesel engine reaches a certain speed, the reduction shaft quickly back to work, and make the diesel engine ignition start; 6, after starting the diesel engine, the electric key dial back to the middle position, speed should be controlled at 600 to 700 rev / min, and a close attention to oil pressure group, the table indicates (working oil pressure sees all kinds of diesel instructions), if no oil pressure indication, should immediately stop inspection; 7, if set low in normal operation, the speed can be gradually increased from 1000 to 1200 rev / min warm-up operation, when the water temperature at 50 ~ 60 ℃, the oil temperature reaches 45 ℃, then the speed to 1500 rev / min, observe the distribution panel frequency meter should be around 50 Hz, voltmeter 380 to 410 volts, adjustable magnetic field rheostat When the voltage is high or low; 8, if the unit is working properly, you can close the generator and negative air switch between plant, then gradually increase the negative plant, power transmission outward; everyone Tips, 1, all kinds of diesel engine should start their diesel maintenance manual requirements, 2, when the regulator If the unit is stored for too long, generator loss of field, voltage build not up, then the available battery charge and magnetism, when the magnetizing field winding L1 (+) connected to the battery positive L2 (-) connected to the negative battery must not take the wrong 3. If you press the button for 10 seconds, can not fire start, should wait a minutes or so and then make a second start, if three consecutive failures, should pinpoint the cause again start. |
Admin>>>
You are the 24566 visitor
Copyright © GuangDong ICP No. 10089450, Mechanical and Electrical Equipment Co., Ltd. Shijiazhuang glow All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 24566 visitor
Copyright © GuangDong ICP No. 10089450, Mechanical and Electrical Equipment Co., Ltd. Shijiazhuang glow All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

